Model | Gentier96E | Gentier96S | Gentier96R | Gentier96C | |
Thermal block | |||||
Sample capacity(wells) | 96 | ||||
Reaction volume | 0-100ul | ||||
Consumable | 0.2ml 96-WELL plates(unskirt)0.2ml 8-strip tubes,0.2ml PCR single tube(Optical flat cap. Clear,frosted,white tube) | ||||
Temperature range | 0℃-100℃ | ||||
Heating/cooling system | Peltier | ||||
Max heating rate | 6.1℃/sec | ||||
Average heating rate | 4.5℃/sec | ||||
Max cooling rate | 5.0℃/sec | ||||
Average cooling rate | 2.8℃/sec | ||||
Temperature accuracy | ±0.1℃ | ||||
Temperature uniformity | ±0.1℃ | ||||
Gradient range | 1℃-40℃ | N/A | 1℃-40℃ | N/A | |
Gradient block | 12row | 12row | 8row | ||
Special temperature protocol | Gradient PCR, Long PCR, Touch Down PCR | Long PCR, Touch Down PCR |
Gradient PCR, Long PCR, Touch Down PCR | Long PCR, Touch Down PCR | |
Heat Lid | |||||
Temperature range | Room temperature-110℃ | ||||
Optical system | |||||
Excitation Source | 6LEDs | 4LEDs | |||
Detector | Photodiode | ||||
Detection position | Excitation and scan at top | ||||
Detection method | 6 channels scanning at the same time, no edge effect | ||||
Detection time | 7 seconds for 96 wells for all channels | ||||
Range of excitation/emission wavelengths(nm) | 1. 465/510(FAM,SYBR Green I,SYTO9,Eva Green, LC Green) 2. 527/563(HEX,VIC,TET,JOE) 3. 580/616(ROX,Texas Red) 4. 632/664(Cy5) 5.680/730(Alexa Fluor680) 6.465/616(FRET) |
1. 465/510(FAM,SYBR Green I,SYTO9,Eva Green, LC Green) 2. 527/563(HEX,VIC,TET,JOE) 3. 580/616(ROX,Texas Red) 4. 632/664(Cy5) |
|||
Probe Taqman Probe,Molecular beacons probe, scorpion probe,FRET | Taqman Probe,Molecular beacons probe, scorpion probe, | ||||
Multiplexing | Up to 6 targets | Up to 4 targets | |||
Fluorescence Linearity | r≥0.990 | ||||
Fluorescence Dynamic Range | Adjustable | ||||
Performance | |||||
Sample Linearity | /r/≥0.999 | ||||
Sample repeatability | Ct value CV≤0.5% | ||||
Sample dynamic Range | 1-1010 | ||||
Software Functions | |||||
Data Analysis Modes | Qualitative analysis, Absolute quantification, Relative quantification, Genotyping analysis, Endpoint analysis, Melt curve analysis, High Resolution Melting | ||||
Control Modes | 10.4touch screen PC direct control WLAN control(one PC can control max 10 unit, and device can be controlled by any PC in the WLAN) |
||||
Sample Drawer | Touch Screen commend | ||||
Data Storage | Upload and download through USB disk, 1000 results can be stored in machine | ||||
Power failure protection | Automaticly start running experiments after power supply, no need wait PC software | ||||
Customize Report | Templetes reserved, report can customized | ||||
Administration Management | Administratior can set functions limits for users | ||||
Transport Locker | Automaticly detect transport locker | ||||
Fault Management | Fault report and analysis,solution instruction | ||||
LIS connection | CSV,Excel,TXT format data output, open port for LIS connection | ||||
Others | |||||
PC operating system | Win7, Win 10 | ||||
Communication Port | 1 ethernet and 3 USB | ||||
Foot pprint(WxDxH) | 355mmX480mmX485mm | ||||
Weight | 30kg | ||||
Power usage | AC100 to 125V/200to 240V(50/60HZ) | ||||
Power consumption | 900VA | ||||
Work environment | Temperature:10℃~30℃ Humidity:20%~85% |