Home Categories Send inquiry

Digital Spring tester

Parameter

1. High precision and high resolution: accuracy 1, minimum reading 0.001N;
2. Three display options: real-time, peak, and automatic peak;
3. Three conversion units: N, kg, lb
4. Peak hold function: capture the test peak;
5. Comparison function: the upper and lower limits are set freely, and the alarm lights automatically alarm for traffic lights and peaks;
6. Automatic peak value function: the peak value holding time (1~99 seconds) can be set freely;
7. Automatic shutdown function: 0~99 minutes without operation automatic shutdown (0 seconds without automatic shutdown);
8. Gravity acceleration function: According to different regions, it can be set freely (9.000~9.999);
9. Calculation function: connected to a computer, it can automatically calculate the maximum value, minimum value and average value of each test;
10. Built-in printer: can print 99 groups of stored measurement data and maximum, minimum, average, etc.

Technical data

Model Number ATH-10 ATH-20 ATH-30
Maximum testing load 10N 20N 30N
Minimum resolution 0.001N
Diameter of the platen 34mm
Maximum free length of

measurable spring

80mm
Length of travel o
displacement scale
60mm
Division value of the

Displacement scale

0.01mm
Indication error ±1%
Power Supply AC 110-220V, 50HZ-60HZ
Power Capability

(without printer)

13W
Power capability

(with printer)

20W
Working temperature 20±10℃
Temperature of storage and

transportation

-27℃~+70℃
Relative temperature 15%~80%RH

Technical data

Model Number ATH- 100 ATH- 150 ATH- 200 ATH- 300 ATH- 500
Maximum testing load 100N 150N 200N 300N 500N
Minimum resolution 0.01N
Diameter of the platen 48mm
Maximum free length

of measurable spring

150mm
Length of travel

of the displacement scale

90mm
Division value of

the displacement scale

0.01mm
Indication error ±1%
Power Supply AC 110-220V, 50HZ-60HZ
Power capability

(without printer)

13W
Power capability

(with printer)

20W
Working temperature 20±10℃
Temperature of storage

and transportation

-27℃~+70℃
Relative temperature 15%~80%RH
Model Number ATH-1000 ATH-2000 ATH-3000 ATH-5000
Maximum testing load 1000N 2000N 3000N 5000N
Minimum resolution 0.1N
Diameter of the platen 108mm
Maximum free length

of measurable spring

200mm
Length of travel of the

displacement scale

150mm
Division value of the

displacement scale

0.01mm
Indication error ±1%
Power Supply AC 110-220V, 50HZ-60HZ
Power capability

(without printer)

13W
Power capability

(with printer)

20W
Working temperature 20±10℃
Temperature of storage

and transportation

-27℃~+70℃
Relative temperature 15%~80%RH